Modular Messaging Help |
|
Home > MAS Administration > MAS - Rules for Creating Port Groups |
![]() |
MAS - Rules for Creating Port Groups |
All port groups are created via the Port Groups dialog box, General tab and given initial settings. See VMSC - MAS - Port Groups - General Tab.
They can then be given additional settings in several different ways:
You can create port groups for PC client applications, the Telephone User Interface (TUI), Call Me, and Fax via the Port Groups dialog box, General tab, using any appropriate name.
You can configure the initial settings for each one in the General tab, then link them to the appropriate field on the Usage tab: PC Clients, Telephone User Interface, Call Me and Fax. See VMSC - MAS - Port Groups - Usage Tab.
When creating these ports, follow these guidelines:
You can create a port group for Message Waiting Indicator (MWI), using any appropriate name.
You can configure the initial settings in the Port Groups dialog box, General tab, then make additional settings via the PBX Interface dialog box. The tab you use within that dialog box, depends on the type of Private Branch Exchange (PBX) interface you are using:
You can create port groups where their usage has been predefined in the Modular Messaging system. In these cases, you must give the port groups specific names so that they are recognized by the system.
You can create these groups and give them initial settings in the Port Groups dialog box, General tab:
![]() |
|