- Maximum Continuous Tone before Hanging Up (ms) Enter the time, in milliseconds, that the voice mail system listens to a dial tone once a caller hangs up, before dropping the line. The range is 0 through 12000, the default is 6000.
- Hangup String Enter the sequence of DTMF digits and call transfer codes (& - = D H N T X P M) that the PBX sends to indicate that a call has terminated (been hung up).
Note:
This field is applicable to only certain switches that support inband integration. Leave this field blank for C-LAN, DMI-4, and RS-232 integrations.
|
|
- Hangup String Timeout (ms) Enter the time, in milliseconds, that the voice mail system waits between digits before validating a hangup string. The range is 0 through 9999, the default is 0.
- Minimum Duration for Drop in Loop Current (ms) Enter the time, in milliseconds, that must elapse before the voice mail system recognizes a true drop in loop current. The range is 0 through 3000, the default is 300. Setting this field to 0 disables this feature.
- Maximum Silence before Hanging Up (ms) Enter the time, in milliseconds, that the voice mail system waits before hanging up, if a user falls silent while recording. The range is 0 through 12000, the default is 6000.