The Disk Diagnostics page shows information about the Redundant
Array of Independent Disks (RAID) hard-disk drive setup in a Message
Storage Server (MSS). If a disk drive is replaced, this page also
provides the rebuild command for an IDE RAID drive, and the rebuild
status for either an MSS-S or MSS-H configuration.
The page displays different information depending on the configuration
of the Message Storage Server (standard or high-availability):
To retrieve disk information about either configuration:
- On the Disk Diagnostics page, click the Disk Information
link.
The system displays the Disk Information page.
- From the drop-down menu, select the disk for which you want
to view information. For the MSS-H configuration, you can select
only the logical drive.
- Click Display.
The system displays the Disk Information results page for that
hard drive.
- Click Return to Main
Note: Information about the IDE drive in the Message
Application Server does not appear on this page. Use
standard Microsoft Windows techniques to view information
about the hard disk drive in an MAS.
MSS-S IDE RAID system information, rebuild command,
and rebuild status
The Disk Diagnostics page provides access to IDE RAID system information
and device status for an MSS standard configuration (MSS-S). If
you replaced an IDE RAID drive, this page provides the rebuild command
and a query link for monitoring the disk rebuild status. For more information
about using this page, see the online help.
To retrieve IDE RAID system information:
- From the MSS Messaging Administration menu, select Diagnostics
> Disk Information.
- The RAID System Information section shows device status. Select
one of the following links:
- Click Return to Main.
MSS-H SCSI RAID system information and status
The Disk Diagnostics page provides access to SCSI RAID system information
and device status for the MSS high-availability configuration (MSS-H).
This page includes information about the size and status (state)
of the logical drive (RAID 5 array), physical devices (disk drives),
and the SCSI RAID controller card.
The logical drive state can be:
- Optimal - fully functional
- Degraded - a problem was detected
- Reconstruct - a faulty disk drive was replaced,
but the disk reconstruction is not complete
The physical device states can be:
- Optimal - fully functional
- Failed drive - faulty disk. For repair information,
see Performing hardware maintenance.
For an S3400-family server, see Replacing
a SCSI RAID drive.
- Missing - the SCSI drive is pulled out
- Replaced drive - a faulty disk drive was replaced,
but the disk reconstruction is not complete
To retrieve SCSI RAID system information:
- From the MSS Messaging Administration menu, select
Diagnostics > Disk Information.
The system displays the Disk Diagnostics page.
- The RAID System Information section provides access to RAID
system information and disk drive rebuild status. To view this
information, select one of the following links:
- Query RAID System Information shows:
- Logical drive name and path, state, number of blocks,
drive size in Megabytes (MB), and block size in bytes.
- Physical device state, number of blocks, drive size
in Megabytes (MB), and block size in bytes.
Note: If one of the SCSI disk drives was
removed, this page does not show the missing device.
- SCSI RAID controller card information, including the
serial number and status. The status is always displays
Optimal if the RAID 5 system is even partly functional.
- Query Rebuild Status shows if a disk drive recovery process
is underway, and how much of the recovery has completed.
Note: You can refresh this page periodically
to monitor the progress of a disk rebuild. The entire
operation takes at least 8 hours to complete, but could
take much longer.
- Click Return to Main.
Top of page
|