Avaya recommends that you enter 2. For C-LAN and Inband integrations, the default value is 2.
- Enable or disable ports, as required, by selecting or clearing the check boxes to the left of each port. All ports are selected by default.
- Port The port number is read only.
- Extension Enter the port extension number. You can enter up to 10 digits. This field is blank by default.
- Incoming Ring Count Enter a number to specify the number of rings before a call on the port is answered. The range is 1 through 9, and the default is 1.
- Primary Id Enter the first part of the PBX integration identifier, known as the logical terminal number (LTN), for serial integration only. You can enter up to 10 characters and digits (including & * # and ,). This field is blank by default.
Note:
This field is applicable to DMI-4 and RS-232 integrations only. Leave this field blank for C-LAN and inband integrations.
|
|
- Secondary Id Enter the second part of the PBX integration identifier, known as the message desk number (MD), for serial integration only. You can enter up to 10 characters and digits (including & * # and ,). This field is blank by default.
Note:
This field is applicable to DMI-4 and RS-232 integrations only. Leave this field blank for C-LAN and inband integrations.
|
|