Avaya

Modular Messaging Help

 Getting Started 
 Administration 
 Maintenance 
 Reference 
 
Home > Maintenance > Getting inside the chassis > Restoring power to the system

Restoring power to the system

To restore power to the system:

  1. For a rack-mount unit: Reattach any cables you might have unplugged from the back of the machine.
  2. Plug the AC power cord back into the power outlet on the unit.
  3. Press the power button on the front of the machine.

    The green power lamp on the front of the machine should light.

  4. On the MAS: When the reboot is complete, log in, and then verify that all installed Modular Messaging services are started. These services all begin with the abbreviation MM. To check or restart messaging services:
    1. Double-click the Monitor icon on the desktop.
    2. In the Monitor window, click Services (Local) in the left pane (if it is not already selected).
    3. In the right pane, scroll down to the list of Modular Messaging (MM) services. Verify that the Status column shows that service is started for each installed messaging service, and that the startup type is set to Automatic.
    4. If any MM service is stopped or if the Status column is blank, do the following to set up all Modular Messaging services correctly:
      1. Click Start > Run to open the Run window.
      2. In the Open field, type the following and press Enter: C:\Avaya_Support\Scripts\serverrecovery.vbs

        The script takes a few seconds to run.

      3. Refresh the screen to verify that all installed MM services are started and set to Automatic.

    5. When finished, close the Monitor window.
  5. Continue with any verification procedures needed to return the system to service.

 

Top of page