To configure ports for QSIG or set emulation, use the Telephony Interface tab.
- In the Voice Mail System Configuration window, click Message Application Servers.
- Click the MAS you want to configure.
- Double-click Telephony Interface.
The system displays the Telephony Interface dialog box, General (QSIG or set emulation) tab.
- Playback Volume Enter a value for the playback volume. The range is – 8 through 8, and the default is 2. We recommend that you enter 2 for 30-port, 24-port, 8-port, or 4-port cards.
- Concurrent Calls Enter the number of ports that connect the MAS to the PBX. The default is set during installation. The range is from 0 to 999.
Note:
The AUDIX TUI supports only up to 24 ports for set emulation, 23 ports for T1 cards, and 30 ports for E1 cards.
|
|
- Port Enable or disable ports as required, by selecting or clearing the check boxes to the left of each port. All ports are selected by default.
- Extension Number Enter the extension number associated with the MAS port. The extension number is required only if you are using linear chain integration with set emulation. You can enter up to ten digits. The Extension Number field is available only with set emulation.
Note:
The Extension Number field is not available with the QSIG telephony interface.
|
|
To activate the new settings, you must restart the MAS.