Made Easy Tool for DEFINITY Media Server Configurations
Issue 5, October 2002
Add IP Solutions
Verify Circuit Packs
- Type change circuit-pack and press Enter.
- On the Circuit Packs - Screen 1, check the Code column to see if it says DSMAPD or MedPro.
- To correct it, go to the entry just above the TN802B that says DSMAPD.
- Type MEDPRO, and press Enter. Changing the one entry automatically changes the entry above it. If it is in IP Trunk mode, you get the following error message:
- To complete the administration, refer to the Administration for Network Connectivity for Avaya MultiVantageTM Software book.
MedPro type requires TN802 with application. Type MEDPRO on circuit-packs form.
Circuit Packs - Screen 1