New Duplicated G3r installations only
- Retrieve the RFA License File with both serial numbers from the RFA Application.
- Type
set time and
press
Enter.
Ensure that the system date and time are set correctly.
- Use one of these installation methods:
- Type
save translation and press
Enter.
After the translations have been copied (about 10 minutes), the system returns an error code, which must be a zero; otherwise, the translations are not copied.
- Type
reset system 4 and press
Enter.
Wait until the system has completely reset before continuing.
- Type
change cabinet 1 and press
Enter.
In the
Carrier Type column change the "B" carrier to
processor and submit the form.
- Type
change system-parameters duplication and press
Enter.
Set the
Enable Operation of SPE Duplication field to
y and submit the form.
- Type
save translation and press
Enter.
After the translations have been copied (about 10 minutes), the system returns an error code, which must be a zero; otherwise, the translations are not copied.
- Type
reset system 3 preserve-license (or
reset system 3 no-preserve-license, since the License File has been saved in translations) and press
Enter.
New simplex and upgraded G3r only
- Type
save translation and press
Enter.
After the translations have been copied (about 10 minutes), the system returns an error code, which must be a zero; otherwise, the translations are not copied.
- Type
reset system 3 and press
Enter.
Wait until the system has completely reset before continuing.
- If the system has IP endpoints registered, unplug the Ethernet cable from the TN799 (C-LAN) circuit pack.
This disconnects (unregisters) all IP endpoints.
- Type
set time and
press
Enter.
Ensure that the system date and time are set correctly.
- Use one of these installation methods:
New or upgraded G3si only
- Retrieve the RFA License File with both serial numbers from the RFA Application.
- If the system has IP endpoints registered, unplug the Ethernet cable from the TN799 (C-LAN) circuit pack.
This disconnects (unregisters) all IP endpoints.
- Type
set time and
press
Enter.
Ensure that the system date and time are set correctly.
- For
duplicated systems only type
status system all and press
Enter.
Ensure that the standby SPE is
not in the maintenance state. If it is, wait for the maintenance state to finish.
- Use one of these installation methods:
Direct connection between the switch and RFA
- Go to the RFA website, and, following the instructions in the "Deliver to G3r/G3si/G3csi" chapter of the RFA Job Aid, deliver the License File.
- If the system has IP endpoints registered, and you unplugged the Ethernet cable from the TN799 (C-LAN) circuit pack, replug the cable.
This re-registers the IP endpoints.
No connection between the switch and RFA
- Go to the RFA website, and, following the instructions in the "Deliver to G3r/G3si/G3csi" chapter of the RFA Job Aid, deliver the License File to your laptop/PC.
- Open the License Installation Tool (LIT) application at your laptop/PC.
- Use the LIT instructions to add a switch connection profile to the tool.
- Use the LIT instructions to install the License File on the switch.
- If the system has IP endpoints registered, and you unplugged the Ethernet cable from the TN799 (C-LAN) circuit pack, replug the cable.
This re-registers the IP endpoints.
Return to Task List