- Type
save translation and press
Enter.
After the translations have been copied (about 10 minutes), the system returns an error code, which must be a zero; otherwise, the translations are not copied.
- Type
reset system 3 and press
Enter.
Wait until the system has completely reset before continuing.
- If the system has IP endpoints registered, unplug the Ethernet cable from the TN799 (C-LAN) circuit pack.
This disconnects (unregisters) all IP endpoints.
- Type
set time and
press
Enter.
Ensure that the system date and time are set correctly.
Direct connection between the switch and RFA
- Go to the RFA website, and, following the instructions in the "Deliver to G3r/G3si/G3csi" chapter of the RFA Job Aid, deliver the License File.
- If the system has IP endpoints registered, and you unplugged the Ethernet cable from the TN799 (C-LAN) circuit pack, replug the cable.
This re-registers the IP endpoints.
No connection between the switch and RFA
- Go to the RFA website, and, following the instructions in the "Deliver to G3r/G3si/G3csi" chapter of the RFA Job Aid, deliver the License File to your laptop/PC.
- Open the License Installation Tool (LIT) application at your laptop/PC.
- Use the LIT instructions to add a switch connection profile to the tool.
- Use the LIT instructions to install the License File on the switch.
- If the system has IP endpoints registered, and you unplugged the Ethernet cable from the TN799 (C-LAN) circuit pack, replug the cable.
This re-registers the IP endpoints.
Return to Task List