DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



R5/R6/R7/R8si to Avaya MultiVantage

Introduction

This section provides the information necessary to upgrade a DEFINITY ® R5si, R6si, R7si, or R8si system with a single carrier or multicarrier PPN to Avaya MultiVantage using the on-site upgrade method.

Refer to these reference books:

For hardware details, see System Description and When to use the TN2401 versus the TN2401/TN2400 sandwich pack.

About circuit-pack carriers

If the system currently being upgraded was originally a System 75, the circuit-pack carrier or cabinet is no longer supported. This table identifies the obsolete carriers and cabinet.

Upgrade from
to

J58890AA
J58890AB
(originally System 75 small-cabinet carriers)

J58890AH carrier

J58890G
(originally System 75XE cabinet)

J58890L cabinet


Note: In some previous upgrades, the control cabinet or carrier replacement was optional. The replacement is required for this upgrade. Use the upgrade instructions in this section, but refer to the System 75 Small-Cabinet to R8si (Blowback) upgrade for instructions on replacing the carrier, and the System 75 XE to R8si (Blowback) upgrade for instructions on replacing the cabinet.

Before you begin the upgrade

Review the Preparation and process steps carefully. These tables describe the tasks that must be completed before the upgrade visit and who is responsible for them.

To prevent the most common upgrade problems, be sure that you have

Task List: R5/R6/R7/R8si to Avaya MultiVantage

Use this task list to upgrade from simplex or duplex R5si, R6si, R7si, or R8si systems to an Avaya MultiVantage PPN.

Ensure that these tasks are complete before the upgrade visit:

  1. Verify the required hardware [Avaya MultiVantage si]

  2. Provide the required tools [Avaya MultiVantage si]

  3. Go to the RFA website [Avaya MultiVantage si]

  4. Pre-upgrade administration [Avaya MultiVantage si]

Perform these tasks during the upgrade visit:

  1. Verify the software version [Avaya MultiVantage si] to identify any software patches.

  2. Verify system status [Avaya MultiVantage si] to check the health of the SPE. Record any customer-placed busy-outs.

  3. Modify external alarm connections [Avaya MultiVantage si] if they change with the upgrade (for sites with external alarm reporting)

  4. Label and connect cables [Avaya MultiVantage si] if you are replacing a carrier or cabinet.

  5. Disable scheduled maintenance and alarm origination [Avaya MultiVantage si]

  6. Check link status [Avaya MultiVantage si]

  7. Record all links and remove only ISDN interface links [Avaya MultiVantage si]

  8. Disable TTI [Avaya MultiVantage si] if it is enabled. Do not skip this step!

  9. Translations can be corrupted if TTI is enabled. Confirm that TTI is completely disabled before you save translation!

  10. Save translation [Avaya MultiVantage si]

  11. Save announcements (TN750 or TN750B only) [Avaya MultiVantage si]

  12. For systems so equipped: Shut down DEFINITY LAN Gateway [Avaya MultiVantage si]

  13. For systems so equipped: Shut down DEFINITY AUDIX system [Avaya MultiVantage si]

  14. Power down cabinet(s) [Avaya MultiVantage si] and unseat any adjuncts. For a high or critical reliability system in an SCC, power down both A and B cabinets.

  15. Verify TDM cables and connectors [Avaya MultiVantage si]. If new TDM terminators and cables are required, install them now.

  16. Remove translation card(s), TN790/B, TN778, TN777B or TN794 or TN794/TN2400 circuit packs [Avaya MultiVantage si]

  17. If the system has no administered BX.25 links, Remove TN765 circuit pack [Avaya MultiVantage si]

  18. For a high or critical reliability system, Replace TN772 duplication interfaces with the TN792 duplication interfaces (R6si or earlier) [Avaya MultiVantage si]

  19. Install TN2404 and TN2401 circuit packs and original translation card(s) [Avaya MultiVantage si]

  20. Power up the system [Avaya MultiVantage si]

  21. Set Daylight Savings Rule [Avaya MultiVantage si]

  22. Make sure the active tone clock is in the active SPE before continuing.

  23. Install the License File [Avaya MultiVantage si]

  24. Administer No-License/Emergency Numbers [Avaya MultiVantage si]

  25. Affix label [Avaya MultiVantage si]

  26. Verify the upgrade [Avaya MultiVantage si]

  27. Verify software version [Avaya MultiVantage si]

  28. Restore busyouts [Avaya MultiVantage si]

  29. If you changed scheduled maintenance parameters, restore the original values. Re-enable scheduled maintenance and alarm notification [Avaya MultiVantage si]

  30. Check customer options [Avaya MultiVantage si]

  31. Register the Switch for Maintenance [Avaya MultiVantage si]

  32. Check link status [Avaya MultiVantage si]

  33. Power up DEFINITY LAN Gateway system [Avaya MultiVantage si]

  34. Power up DEFINITY AUDIX system [Avaya MultiVantage si]

  35. Resolve alarms [Avaya MultiVantage si]

  36. Restore any customer-placed busy-outs before you run the acceptance tests!

    If the system contains adjuncts such as DEFINITY AUDIX, reseat them as required before you run the acceptance tests.

  37. Run acceptance tests [Avaya MultiVantage si]

  38. Re-enable TTI [Avaya MultiVantage si]

  39. Restore announcements (TN750 or TN750B only)[Avaya MultiVantage si] or Rerecord announcements [Avaya MultiVantage si] as necessary

  40. Check SPE [Avaya MultiVantage si]

  41. Save announcements and translation [Avaya MultiVantage si]

  42. Return equipment [Avaya MultiVantage si]


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2002 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.