Previous page Next page

Setting the IEDR Threshold for Internal Errors

You can set the threshold at which the switch will shutdown a port. By default this threshold is set to 10 internal errors in a 5-second time period. You can set the threshold to any number between 5 and 500 internal errors in a 5-second time period. This setting is global for all ports that have been enabled for IEDR including ports configured for hunt groups.

To set the IEDR threshold:

  1. Enter Global Configuration mode.
  2. The CLI displays the (configure)# prompt.

  3. Enter the following command:
  4. set internal-error-threshold <threshold>


Previous page Next page