Setting the Temperature System
You can set the upper and lower temperature warning systems for the switch backplane and slot 1. These warning systems cause the following to happen if the temperatures you set are reached:
- Shutdown Temperature--The switch shuts down if this temperature is reached.
- Upper Warning Temperature--The switch generates an alarm if this temperature is reached. If the Shutdown Temperature is reached, once the temperature drops below the Upper Warning Temperature, the switch restarts.
- Lower Warning Temperature--The switch generates an alarm if this temperature is reached. Once the temperature rises above this temperature, the alarm is cleared.
- Low Limit Temperature--The switch generates an alarm if this temperature is reached.
See Figure�29 for the default temperature system settings. You can set the temperature system using either the Web Agent or the CLI.