Previous page Next page

Connect an Analog Station or 2-Wire Digital Station����

This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations (2500), analog Central Office (CO) trunks, Direct Inward Dial (DID) trunks, and external alarms.

  1. Choose a peripheral to connect (such as a 2-wire digital station).
  2. Choose the Media Module to use and its Media Gateway and slot number; for example, MM711 Analog Media Module, Media Gateway 002, Slot V2.
  3. Choose a port circuit on the MM711 Media Module; for example, port 03.
  4. Install cross-connect jumpers to connect the pins from the 2-wire digital station to the appropriate pins on the MM711 Media Module. Table 15 shows a pinout chart for two-wire stations.
Table 15. Two-Wire Station Pinout Chart���.
Jack Name
1
2
3
4
5
6
7
8
BRI-T


+TX
+RX
-RX
-TX
-V
GND
ADJUNCT
+Vadj
T0
-V
GNDVoice
RRVoice
+V
S0
TTVoice
DSS (QUEST)
DTX

DRX


OKdig
-V
+V
DSS (ISDN)








BRI-A


GND
TX
RX
-V


BRI-U



TX
RX

-V
GND
DCP
TX1
TX2
RX1


RX2
-V
+V
ANALOG



TIP
RING



HANDSET


-TX
+RX
-RX
+TX


  1. Administer using Administrator's Guide for Avaya MultiVantage Software.

Figure 7. 2500-Type Analog Telephone Wiring���


Figure notes
1 2500-Type Analog Station
2 MM711 Analog Media Module, Position 1V301


Previous page Next page