Connect an Analog Station or 2-Wire Digital Station����
This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations (2500), analog Central Office (CO) trunks, Direct Inward Dial (DID) trunks, and external alarms.
- Choose a peripheral to connect (such as a 2-wire digital station).
- Choose the Media Module to use and its Media Gateway and slot number; for example, MM711 Analog Media Module, Media Gateway 002, Slot V2.
- Choose a port circuit on the MM711 Media Module; for example, port 03.
- Install cross-connect jumpers to connect the pins from the 2-wire digital station to the appropriate pins on the MM711 Media Module. Table 15 shows a pinout chart for two-wire stations.
Table 15. Two-Wire Station Pinout Chart���.
| Jack Name |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
| BRI-T |
|
|
+TX |
+RX |
-RX |
-TX |
-V |
GND |
| ADJUNCT |
+Vadj |
T0 |
-V |
GNDVoice |
RRVoice |
+V |
S0 |
TTVoice |
| DSS (QUEST) |
DTX |
|
DRX |
|
|
OKdig |
-V |
+V |
| DSS (ISDN) |
|
|
|
|
|
|
|
|
| BRI-A |
|
|
GND |
TX |
RX |
-V |
|
|
| BRI-U |
|
|
|
TX |
RX |
|
-V |
GND |
| DCP |
TX1 |
TX2 |
RX1 |
|
|
RX2 |
-V |
+V |
| ANALOG |
|
|
|
TIP |
RING |
|
|
|
| HANDSET |
|
|
-TX |
+RX |
-RX |
+TX |
|
|
- Administer using Administrator's Guide for Avaya MultiVantage Software.
Figure 7. 2500-Type Analog Telephone Wiring���
1 2500-Type Analog Station
|
2 MM711 Analog Media Module, Position 1V301
|