Table 123. Maintenance Features for Avaya G700 with S8300 Media Server �
Supported Feature |
Controller S8700/ S8300 |
Notes |
Attendant Console alarm LED and alarm report acknowledgement LED |
Yes |
Status of G700 alarms is not available on the Attendant Console with a legacy controller. |
Automatic Trunk Measurement System (ATMS) |
No |
Not available for analog trunks terminating on a Media Module. |
DS0 Looparound connection |
No |
|
DS1 CPE Loopback |
Yes |
Test is controlled by the DS1 Media Module. |
DS1 Synchronization |
|
Timing sync is local to the G700 so DS1 sync is controlled by the G700. |
Enable/Disable Media Module tests |
Yes |
|
Enable/Suspend alarm origination |
No |
Not supported by S8700 platform. |
Environment tests and alarms for S8300 |
|
Not available for S8300 in R1. |
ISDN loop around connection |
Yes |
|
ISDN test call |
No |
Not available for ISDN trunks terminating on a DS1 Media Module. |
LED tests |
Partial |
Works with Media Module LEDs but not with the G700 alarm LED. |
System Configuration Maintenance Object |
No |
Not needed for Media Module board insertion. Indicates that a board is present but that the board does not respond to a query for board type. |
System Link test for PRI control link for ISDN DS1 Media Module |
No |
Layer 2 of a PRI link is terminated in the G700, so this does not apply to Avaya G700 with S8300 Media Server. A new MO is added for the status and alarming of H.248 links. |
System tone test call for G700 |
No |
Requires changes to the call processing software in the S8300 and the G700 |
Terminating trunk transmission test lines |
No |
|
Test MO command |
Yes |
Support syntax of Media Module location |
Test S8300 hardware |
Limited |
|
Test of G700 resources: Archangel Network Control Element Packet Interface TDM clock Tone generator Tone detectors |
No |
Provided by G700 software in a future release. G700 architecture specifies these resources as G700 resources, not S8300 resources. |
Tests of Media Modules |
Partial |
Limited by the tests available in R1. |
Touch Tone Receiver facility test call |
No |
|
Touch Tone Receiver level |
No |
|
Trunk facility test call |
Yes |
|
Write Physical Angel command |
No |
|
System synchronization |
No |
|
|
|
|