Control Channel Looparound Test (#52)

This test queries the Media Module for its Media Module code and vintage and verifies its records.

Table 63. Test #52 Control Channel Looparound Test
Error Code
Test Result
Description/ Recommendation
None 2100
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.

FAIL
The Media Module failed to return the Media Module code or vintage.
Retry the command a maximum of 5 times.
If the problem continues, replace the Media Module.
Retry the command a few times a maximum of 5 times.

PASS
Communication with this Media Module is successful.
Any
NO BOARD
The test could not relate the internal ID to the port (no board). This could be due to incorrect translations, no board is inserted, an incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1 GGGVS command to administer the DS1-MM if it is not already administered.
If the board was already administered correctly, check the error log to determine whether the board is hyperactive. If this is the case, the board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.