SAKI Sanity Test (#53)

CAUTION:


This test resets the Media Module. The test is highly destructive and can only be initiated by a system technician-demanded reset board GGGVS command.

Table 64. Test #53 SAKI Sanity Test �
Error Code
Test Result
Description/ Recommendation
None
ABORT
System resources required for this test are not available.
Retry the reset board command at 1-minute intervals a maximum of 5 times.
1005
ABORT
Wrong Media Module configuration to run this test. This error applies only to DS1 Interface Media Modules. It means the DS1 Interface Media Module is providing timing for the system, and therefore, it cannot be reset without major system disruptions.
If the Media Module needs to be reset, then set synchronization to another DS1 Interface Media Module or to the Tone-Clock Media Module and try again.
1015
ABORT
Port is not out-of-service.
Busyout the Media Module.
Execute the reset board command again.
2100
ABORT
System resources required for this test are not available.
Retry the reset board command at 1-minute intervals a maximum of 5 times.
1
FAIL
The Media Module failed to reset.
2
FAIL
The Media Module failed to restart.
Execute the reset board command again.
If the problem persists, replace the Media Module.

PASS
The Media Module initializes correctly.
Run the Short Test Sequence.
Any
NO BOARD
The test could not relate the internal ID to the port (no board). This could be due to incorrect translations, no board is inserted, an incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1 GGGVS command to administer the DS1-MM interface if it is not already administered.
If the board was already administered correctly, check the error log to determine whether the board is hyperactive. If this is the case, the board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.