Previous page Next page

G700 Subsystems Maintained by MultiVantage

The MultiVantage subsystems are listable via the 'list config' command and, in most cases, have some maintenance activities involved.

Note: 'list config' all on the MultiVantage SAT gives you complete information, including whether or not stations have been administered on a port. 'show mg list_config' on the G700 MGP gives you information for the installed equipment in that G700.

The G700 subsystems that are applicable to MultiVantage maintenance considerations are identifiable by the presence of 'angels'. Angels may be either physical or virtual, and both types use the CCMS message. Table 39 lists the applicable subsystems and how they are maintained.

Table 39. G700 Subsystems Maintained by MultiVantage
Subsystem
Angel Maintenance Type
Any Media Module
Physical Angel
Messaging Daughter Board (part of the S8300)
Virtual Angel
Announcement Circuitry (part of the MGP)
Virtual Angel