Table 15. TEST #35 Port Diagnostic Test �
Error Code |
Test Result |
Description/ Recommendation |
|
ABORT |
System resources required to run this test were not available. Retry the command at 1-minute intervals a maximum of 5 times. |
1000 |
ABORT |
System resources required to run this test were not available. The port may be busy with a valid call. Enter display port GGGVSpp command to determine the trunk group/member number of the port. Use the status trunk command to determine the service state of the port. If the port is in use, wait until the port is idle before testing. If the port status is active but the port is not in use (no calls), check the error log for Error Type 513. The port may be locked up. If the port status is idle, busyout and release the trunk, and retry the command at 1-minute intervals a maximum of 5 times. If the test continues to abort, check for wiring errors toward the CO which may cause the trunk to lock up. If the wiring is good and the test continues to abort, replace the circuit pack. |
1004 |
ABORT |
The port was seized by a valid call during the test. Enter display port GGGVSpp to determine the station extension, attendant number, or trunk group/member number of the port. Use the status station, status attendant, or status trunk command to determine the service state of the port. If the port is in use, wait until the port is idle before testing. Attendants are always in use (off-hook) if the handset is plugged in and the port is not busied out. Retry the command at 1-minute intervals a maximum of 5 times. |
1018 |
ABORT |
Test disabled via administration. Verify that the Maintenance Tests? field on the Trunk Group Form is set to n. To enable the test, issue the change trunk-group x command (x is the trunk group number). Then change the entry in the Maintenance Tests? field to y. |
2000 |
ABORT |
Response to the test was not received within the allowable time period. |
2100 |
ABORT |
Could not allocate the necessary system resources to run this test. Retry the command at 1-minute intervals a maximum of 5 times. |
61446 |
FAIL |
Battery feed test failed. A loop current fault was detected. This is most probably an incoming CO-line problem. This failure code is only reported by the TN2139 Italian DID Media Module. Check the incoming CO-line for loop current. If none is detected refer the problem to the CO. If the CO-line checks out OK, the failure must be on the DID port. Replace the Media Module. |
61456 |
FAIL |
Battery feed test failed. An on-board problem was detected. This port is out-of-service. Replace Media Module. |
61472 |
FAIL |
Battery feed test failed. A problem with the incoming CO-line was detected. Check the incoming CO-line for proper operation. If warranted, refer the problem to the CO. If the CO-line is not at fault, the failure must be on the DID port. Replace the Media Module. |
|
PASS |
Current flow was detected for this port. User-reported troubles on this port should be investigated using other port tests and by examining connections. Refer problem to the CO. |
Any |
NO BOARD |
The test could not relate the internal ID to the port (no board). Check to ensure that the board translations are correct. Translate the board, if necessary. Issue the busyout board command. Issue the reset board command. Issue the release busy board command. Issue the test board command. This should re-establish the linkage between the internal ID and the port. If the problem persists, replace the circuit pack. |
|