Previous page Next page

Port Audit Update Test (#36)

This test sends updates of the DID port translation for all ports on the Media Module that have been translated. The update is non-disruptive and guards against possible corruption of translation data contained on the Media Module. No response message is expected from the Media Module once it receives translation updates. The port translation data includes:

Table 16. TEST #36 Port Audit Update Test
Error Code
Test Result
Description/ Recommendation

ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals a maximum of 5 times.
1006
ABORT
The port is out of service, perhaps busied out.
Use display port GGGVSpp to determine the trunk group/member number of the port. Use status trunk to determine the service state of the port. If the port is out of service, wait until the port is in service and idle before testing.
If the port status is in service and idle, then retry the command at 1-minute intervals a maximum of 5 times.
2100
ABORT
Could not allocate the necessary system resources to run the test.
Retry the command at 1-minute intervals a maximum of 5 times.

FAIL
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.

PASS
This test passed. Translation information was successfully updated on the Media Module.
If signaling troubles are reported (Error Types 1, 257, or 513), verify translation for this port.
Refer problem to the CO.
Any
NO BOARD
The test could not relate the internal ID to the port.
Check to ensure that the board translations are correct. Translate the board, if necessary.
Issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board command. This should re-establish the linkage between the internal ID and the port.
If the problem persists, replace the circuit pack.


Previous page Next page