Maintenance Commands
Categories of maintenance commands
- Avaya MultiVantage Software 1.2 SAT commands
- Avaya G700 Media Gateway Processor CLI commands
Since the Media Module have many of the same Maintenance Objects as the DEFINITY server circuit packs, many of the same operations apply, as follows:
- The 'test mo logical xxx physical xxx' command works with the physical address of a Media Module Maintenance Object.
- The 'enable/disable MO logical xxx physical xxx' commands work with the physical address of a Media Module Maintenance Object.
- All Media Modules and their associated ports can be busied out and released from the busyout state on demand from the SAT.
Note: A MultiVantage warning alarm and associated hardware error with error code 18 is generated when a Media Module is busied out.
- All Media Modules can be reset on demand from the SAT by use of the 'reset board' command.
CAUTION: This is a destructive test so the Media Module must be busied out before a demand reset can be done.
- If an invalid G700 number is entered with the test command for a Media Module board or port, the following message is displayed: "xxxx" port/board is not valid.
- Tests that are called for but that cannot run on a Media Module abort with the abort code 1412.
- A request for a demand test, a reset, or busy out of the module (board) location for the S8300 Media Server aborts.