Digital Line Electronic Power Feed Test(#11)

MM711 boards provide power to the terminals. Therefore this will be an EPF restoral test. The test procedure and its response is same as that of EPF. If the over current persists the power will be shut off automatically and an EPF_off_overcurrent message is sent uplink.

Table 22. TEST#11 Digital Line Electronic Power Feed Test �
Error Code
Test Result
Description/ Recommendation

ABORT
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be busy with a valid call.
Enter display port GGGVSpp to determine the station extension or attendant number of the port. Use status station or status attendant to determine the service state of the port. If the port is in use, wait until the port is idle before testing. Attendants are always in use (off-hook) if the handset is plugged in and the port is not busied out.
If the port status is idle, then retry the command at 1-minute intervals a maximum of 5 times.

FAIL
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.

PASS
Electronic Power Feed Test passed. The message to turn on the power to the station was successfully sent to the port.
Although this test will never actually return a FAIL result except for the Internal system error described above, it will log an error indicating the real results of the test. Check the Error Log for any entries with Error Types 767 or 769 after the test completes.
If Error Type 767 appears in the Error Log, this indicates that the test sensed no problems with the power to the station. To verify that the station is powered up correctly, run a self-test on the station and check that all the feature buttons are operating.
If Error Type 769 appears in the Error Log, this indicates some problem with the power to the station. Check for a short in the wiring, a damaged jack, a defective voice terminal, or an incorrect type of terminal.
Any
NO BOARD
The test could not relate the internal ID to the port.
Check to ensure that the board translations are correct. Translate the board, if necessary.
Issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board command. This should re-establish the linkage between the internal ID and the port.
If the problem persists, replace the circuit pack.