Table 23. TEST #16 DIG-LINE Station Lamp Updates Test �
Error Code |
Test Result |
Description/ Recommendation |
|
ABORT |
Internal system error Retry the command at 1-minute intervals a maximum of 5 times. |
1 |
ABORT |
This port may have been busied out by system technician. Look in the Error Log for Error Type 18 (port busied out) for this port. If this error type is present, then release the port via the release station <extension> command and run the test again. Make sure that the terminal is connected. Retry the command at 1-minute intervals a maximum of 5 times. |
3 |
ABORT |
Station may be in ready-for-service or out-of-service state. Use status station command to verify state of station. Make sure the terminal is connected. Retry the command at 1-minute intervals a maximum of 5 times. |
1000 |
ABORT |
System resources required to run this test are not available. The port may be busy with a valid call. Use display port GGGVSpp to determine the station extension or attendant number of the port. Use status station or status attendant to determine the service state of the port. If the port is in use, wait until the port is idle before testing. Attendants are always in use (off-hook) if the handset is plugged in and the port is not busied out. If the port status is idle, then retry the command at 1-minute intervals a maximum of 5 times. |
1392 |
ABORT |
This port is currently a TTI port and the test will not execute on it. Verify that the port is a TTI port using either the display port command (the display shows that the port is a TTI port) or the list config command (the display shows a "t" for the port). If either list config or display port indicates that the port is not a TTI port, escalate the problem. If both commands indicate that the port is a TTI port, the abort is correct, and no action is necessary. |
|
FAIL |
Internal system error Retry the command at 1-minute intervals a maximum of 5 times. |
|
PASS |
The message to light all of the station lamps was sent successfully to the port. Observe the station lamps being lit when running the test. If all lamps do not light, the other Digital Line test results may indicate related problems that do not allow the lamps to light. Investigate by using other Digital Line port tests, and by examining the station, wiring, and connections. |
Any |
NO BOARD |
The test could not relate the internal ID to the port. Check to ensure that the board translations are correct. Translate the board, if necessary. Issue the busyout board command. Issue the reset board command. Issue the release busy board command. Issue the test board command. This should re-establish the linkage between the internal ID and the port. If the problem persists, replace the circuit pack. |