Table 24. TEST#17 Station (Digital) Audits Test �
Error Code |
Test Result |
Description/ Recommendation |
1 |
ABORT |
Switchhook audit timed out. |
2 |
ABORT |
ID request fails, health bit returned from voice terminal is bad. Make sure voice terminal is connected and repeat test. If test fails, replace voice terminal and repeat test. |
3 |
ABORT |
Look for Error Type 769 logged against DIG-LINE and follow the procedures in the associated footnote. If any additional problems are found, rerun the test. |
4 |
ABORT |
Internal system error Resolve any outstanding Media Module maintenance problems. Retry the command at 1-minute intervals a maximum of 5 times. |
5 |
ABORT |
Ringer update aborted due to station being in ready-for-service or out-of-service state. |
6 |
ABORT |
This port may have been busied out by system technician. Look in the Error Log for Error Type 18 (port busied out) for this port. If this error is present, release the port via release station Make sure that the terminal is connected. Retry the command at 1-minute intervals a maximum of 5 times. |
1000 |
ABORT |
System resources required for this test are not available. |
1392 |
ABORT |
This port is currently a TTI port and the test will not execute on it. Verify that the port is a TTI port using either the display port command (the display shows that the port is a TTI port) or the list config command (the display shows a "t" for the port). If either list config or display port indicate that the port is not a TTI port, escalate the problem. If both commands indicate that the port is a TTI port, the abort is correct, and no action is necessary. |
2000 |
ABORT |
Response to the test was not received in the allowable time period. |
|
FAIL |
Internal system error Retry the command at 1-minute intervals a maximum of 5 times. |
|
PASS |
Station Audits passed. This Digital Port Media Module is functioning properly. If complaints persist, investigate by using other port tests, and by examining the station, wiring, and connections. |
Any |
NO BOARD |
The test could not relate the internal ID to the port. Check to ensure that the board translations are correct. Translate the board, if necessary. Issue the busyout board command. Issue the reset board command. Issue the release busy board command. Issue the test board command. This should re-establish the linkage between the internal ID and the port. If the problem persists, replace the circuit pack. |
|