Previous page Next page

Definitions of LEDs

Table 99 illustrates the LED definitions.

Table 99. LED Definitions �
No.
LED Name
Description
LED States
1
ALM
Alarm Status Color is RED

OFF - No alarms exist
ON (RED) - Alarm exists on the chassis itself
2
PWR
Alarm Status Color is GREEN
OFF - Power is down
ON - Power is up
Blinking - every 1.2 seconds (400ms on, 800ms off) when 5 volts power is not available to the riser board and the Media Modules
3
CPU
CPU Operation Color is GREEN
OFF - CPU is in boot operation or is running BIST
ON - CPU boot operation and BIST completed
4
MSTR
Master/Slave Status Color is GREEN
OFF - Slave box of the stack
ON - Master of the stack and redundant cable is not present or not active
1 Blink every 1.5 sec - Master of the stack and active redundant cable
5
a
LNK port 51-66, Ext 1-2
Port Status Color is GREEN
OFF - Port disabled or not existent. At phase 1, or link fail of Giga ports.

ON - Port is enabled and link is OK.

1 Blink every 1.5 sec - Link test fail (of 10/100M ports only at phase 1)

2 Blinks every 1.5 sec - Partition

b
COL
Port 51-66, Ext 1-2
Collision
(GREEN)
OFF - No collision or FDX port

ON - Collision occurred on line

c
Tx
Port 51-66, Ext 1-2
Transmit to line
(GREEN)
OFF - No transmit activity

ON - Data transmitted on line

d
Rx
Port 55-66, Ext 1-2
Receive from line
(GREEN)
OFF - To receive activity

ON - Data received from the line

e
FDX
Port 51-66, Ext 1-2
Half/Full Duplex
(GREEN)
OFF - Half Duplex mode of operation

ON - Full Duplex mode of operation, or for 10/100Base-T ports when link test fail with auto-negotiation enabled

f
FC*
Port 51-66, Ext 1-2
Symmetric Flow Control
(GREEN)
OFF - Port is in an Asymmetric Flow control mode, or in Flow Control mode disabled, or it is in half duplex

ON - Port is in full duplex and in a symmetric Flow Control mode

g
HSpd
Port 51-66, Ext 1-2
High Speed
(GREEN)

OFF - 10Base-T or for an expansion port that does not exist

ON - 100Base-T, 100Base-F, 1000Base-X, and OC-12, or for 10/100Base-T ports when link test fail with auto-negotiation enabled

h
LAG
Port 51-66, Ext 1-2
Link Aggregation "Trunking"
(GREEN)
OFF - No LAG defined with this port

ON - Port belongs to a LAG
6
Data
16 data expansion ports 51-66
(GREEN)
OFF - see notes on No. 5 a-h
ON - see notes on No. 5 a-h
7
EXT 1
RJ 45 to Non-Avaya equipment
(GREEN)
OFF - see notes on No. 5 a-h
ON - see notes on No. 5 a-h
8
EXT 2
RJ 45 to Non-Avaya equipment
(GREEN)
OFF - see notes on No. 5 a-h
ON - see notes on No. 5 a-h

* For Giga ports, when auto-negotiation is enabled and the link is down, FC LED reflects the last mode
If the user resets the module/stack, then all of the module's/stack's LEDs light on (test lamp) for 150ms. The COL, Tx, and Rx LED signals must be at least 150ms.


Previous page Next page