Install Telephones Used Only for Emergency
Transfer (Trunk/Auxiliary Field)���
- Connect a pair of wires between the -48V and GRD terminals on the yellow emergency transfer row/connecting block and the EM TRANS RELAY PWR terminal. See Connections for Telephone Used for Emergency Transfer.
- Connect Central Office (CO) trunk leads from the purple field to TC terminals on the yellow emergency transfer row/connecting block for each trunk.
- Connect CO trunk leads from the green field to TK terminals on the yellow emergency transfer row/connecting block for each trunk.
- Connect ST leads on the yellow emergency transfer row/connecting block for each emergency transfer telephone to the assigned terminal in the blue or white station distribution field. The ST terminal leads should be terminated on the following pairs: 1, 4, 7, 10, 13, 16, 19, or 22 (the first pair of any 3-pair group).
- Install the telephone:
- Connect telephone to the information outlet.
- Install patch cords/jumper wires between the media gateway side and the station side of the station distribution field on the MDF.
|
|