Install Telephones Used for Emergency Transfer
and as Normal Extension (Trunk/Auxiliary Field)���
- Connect a pair of wires between the -48V and GRD terminals on the yellow emergency transfer row/connecting block to the EM TRANS RELAY PWR terminal. See Connections for Telephone Used for Emergency Transfer and as Normal Extension.
- Connect CO trunk leads from the purple field to TC terminals on the yellow emergency transfer row/connecting block for each trunk.
- Connect CO trunk leads from the green field to TK terminals on the yellow emergency transfer row/connecting block for each trunk.
- Connect telephone leads from the purple analog line circuit pack row/ connecting block to the LC terminals on the yellow emergency transfer row/connecting block for each telephone.
- Connect ST leads on the yellow emergency transfer row/connecting block for each emergency transfer telephone to the assigned terminal in the blue or white station distribution field.
- Install the telephone:
- Connect telephone to the information outlet.
- Install patch cords/jumper wires between the media gateway side and the station.
|
|