Table 149. Technician-Demanded Tests
| Order of Investigation |
Short Test Sequence |
Long Test Sequence |
Reset Board Sequence |
test ds1-loop |
D/ND* |
| Echo Cancellation Test (#1420) |
|
X |
|
|
D |
| Control Channel Loop Test (#52) |
|
X |
|
|
ND |
| NPE Connection Audit Test (#50) NOTE: This test will ABORT with Error Code 1412 |
|
|
|
|
|
| Loss of Signal Alarm Inquiry Test (#138) |
X |
X |
|
|
ND |
| Blue Alarm Inquiry Test (#139) |
X |
X |
|
|
ND |
| Red Alarm Inquiry Test (#140) |
X |
X |
|
|
ND |
| Yellow Alarm Inquiry Test (#141) |
X |
X |
|
|
ND |
| Major Alarm Inquiry Test (#142) |
X |
X |
|
|
ND |
| Minor Alarm Inquiry Test (#143) |
X |
X |
|
|
ND |
| Slip Alarm Inquiry Test (#144) |
X |
X |
|
|
ND |
| Misframe Alarm Inquiry Test (#145) |
X |
X |
|
|
ND |
| Translation Update Test (#146) |
X |
X |
|
|
ND |
| SAKI Sanity Test (#53) |
|
|
X |
|
D |
| Internal Looparound Test (#135) Note: This test will ABORT with Error Code 1412 |
|
|
X |
|
D |
| *D = Destructive; ND = Nondestructive |