A MG-DS1 Interface Media Module raises a Red alarm when the framing pattern of the incoming DS1 bit stream has been lost. The Red Alarm Inquiry Test checks the framing status of a MG-DS1 Interface Media Module. A MG-DS1 Interface Media Module takes 3 seconds to recognize and report a Red alarm and 10 seconds to recognize and report the resolution of a Red alarm.
When the MG-DS1 Interface Media Module detects a Red alarm, the Media Module transmits a Yellow alarm to the remote DS1 endpoint and sends a RED ALARM message to the maintenance software. After the Red alarm is confirmed, the maintenance software places all trunks or ports of the Media Module into the out-of-service state. The inquiry test runs every 10 minutes until the Red alarm is cleared.
When the Red alarm is cleared, the MG-DS1 Interface Media Module stops transmitting the Yellow alarm to the remote DS1 endpoint. The maintenance software restores all trunks or ports of the MG-DS1 Interface Media Module to the service state it was in before the Red alarm occurred.
If the MG-DS1 Interface Media Module is administered using DMI-BOS signaling, the MG-DS1 Interface Media Module raises a Loss of Multiframe Alarm (LMA) when it cannot interpret the incoming signaling bits to synchronize to the multiframe pattern received in the 24th channel. Once the MG-DS1 Interface Media Module detects an LMA, the Media Module transmits a Remote Multiframe Alarm (RMA) to the remote DS1 endpoint. Maintenance software handles both Red alarm and LMA alarm(s) using the same mechanism.
|
|
|