Major Alarm Inquiry Test (#142)

The Major alarm raised by a MG-DS1 Interface Media Module indicates that the average bit error rate on the DS1 facility is greater than 1/1000. The Major Alarm Inquiry Test is used to determine that the received DS1 bit error rate is greater than 1/1000. The MG-DS1 Interface Media Module takes 10 seconds to recognize and report a Major alarm and 10 seconds to recognize and report that a Major alarm condition is cleared.

When the MG-DS1 Interface Media Module detects a Major alarm, it sends a MAJOR-ALARM message to the maintenance software. (32-channel interfaces send a YELLOW alarm to the far end). After the maintenance software receives a MAJOR-ALARM message, the Major Alarm Inquiry Test is initiated to confirm the Major alarm on the MG-DS1 Interface Media Module. The Inquiry Test runs every 10 minutes until the Major alarm is cleared. The maintenance software places all trunks or ports on the Media Module in the out-of-service state if the Major alarm persists for more than 20 minutes.

When the Major alarm is cleared, the maintenance software restores all trunks or ports on the Media Module to their previous service state before a Major alarm occurs.

Table 156. TEST #142 Major Alarm Inquiry Test
Error Code
Test Result
Description/ Recommendation
ABORT
Internal system error
Retry the command at 1-minute intervals a maximum of 5 times.
2000
ABORT
Response to the test was not received within the allowable time period. This may be due to hyperactivity. Error Type 1538 in the error log indicates hyperactivity. The hyperactive Media Module is out of service and one or more of the following symptoms may be exhibited.
The MG-DS1 tests (such as Test #138 and Test #139) are aborting with error code 2000.
The tests run on the ports of this Media Module are returning a no board result.
A busyout or a release command has no affect on the test results.
A list config command shows that the Media Module and the ports are properly installed.
When hyperactivity occurs, the Media Module is isolated from the system, and all of the trunks for this Media Module are placed into the out of service state. The system will try to restore the Media Module within 15 minutes. When no faults are detected for 15 minutes, the MG-DS1 interface Media Module is restored to normal operation. All of the trunks for the MG-DS1 interface Media Module are then returned to the in service state. Hyperactivity is often caused by the associated facility. In such a case, faults (such as slips, misframes, or blue alarms) would be entered in the error log. In addition, many hardware errors would be logged against the associated trunk circuits. If the facility is OK and the error occurs again after 15 minutes, replace the Media Module.
2100
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals for a maximum of 5 times.

FAIL
If the MG-DS1 connects to a T1 network facility or to another switch, do the following:
The performance of the DS1 link between the MG-DS1 interface Media Module and the remote DS1 endpoint is very poor. Enter the list measurement ds1-log GGGVS command to read the error seconds measurement.
Verify that both endpoints of the DS1 link are administered using the same signaling mode, framing mode, and line coding.
Contact T1 Network Service or the technician at the remote switch to diagnose the equipment.
Check the physical connectivity of the MG-DS1 interface Media Modules and the cable.
Replace the local MG-DS1 interface Media Module, and repeat the test.

FAIL (cont'd.)
If the MG-DS1 connects to a line-side terminating device (for example, a PRI terminal adapter), do the following:
The performance of the DS1 link between the MG-DS1 interface Media Module and the line-side terminating device is very poor. Enter the list measurement ds1-log GGGVS command to read the error seconds measurement.
Verify that the switch DS1 and the line-side terminating device are administered using the same signaling mode, framing mode, and line coding.
Investigate the maintenance status of the line-side terminating device. Refer to the 'Line-Side Terminating Device Operating Manual' for information.
Contact the vendor of the line-side terminating device to diagnose the equipment.
Check the physical connection of the MG-DS11 interface Media Module to the terminating device, and check the premise distribution system (or the intra-premise wiring) for physical connection failures.
Replace the local MG-DS1 interface Media Module and repeat the test.
PASS
No Major alarm is detected in the MG-DS1 Interface Media Module.
Any
NO BOARD
The test could not relate the internal ID to the port (no board). This could be due to incorrect translations, no board is inserted, an incorrect board is inserted, or an insane board is inserted.
Ensure that the board translations are correct. Execute the add ds1 GGGVS command to administer the MM-DS1 interface if it is not already administered.
If the board was already administered correctly, check the error log to determine whether the board is hyperactive. If this is the case, the board is shut down. Reseating the board will re-initialize the board.
If the board was found to be correctly inserted in step 1, then issue the busyout board command.
Issue the reset board command.
Issue the release busy board command.
Issue the test board long command.
This should re-establish the linkage between the internal ID and the port.