Previous page Next page

Technician-Demand Tests: Descriptions and Error Codes

Always investigate tests in the order presented in the table below when inspecting errors in the system. By clearing error codes associated with the NPE Audit, for example, you may also clear errors generated from other tests in the testing sequence.

Table 182. Technician-Demand Tests
Order of Investigation
Short Test Sequence
Long Test Sequence
Reset Board Sequence
D/ND*
NPE Audit Test (#50)

Note: This Test will ABORT with code 1412




Ringing Application Test (#51) (a)

Note: This Test will ABORT with code 1412




Control Channel Looparound Test (#52)
X
X

ND
SAKI Sanity Test (#53) (b)

X
D

Neon Test (#220) (c)
Note: This Test will ABORT with code 1412
X
X

ND
*D = Destructive; ND = Nondestructive