Control Channel Looparound Test (#52)

This test queries the Media Module for its vintage to verify angel communication.

Table 183. TEST #52 Control Channel Looparound Test
Error Code
Test Result
Description/ Recommendation
None 2100
ABORT
System resources required for this test are not available.
Retry the command at 1-minute intervals a maximum of 5 times.

FAIL
The test failed because the Media Module failed to return the Media Module code or vintage.
Retry the command for a maximum of 5 times.
If the test still fails, issue the busyout board, reset board, and release busy board commands, and then retest.
If the problem continues, replace the Media Module.
Run the test again.

PASS
Communication with this Media Module is successful.
Any
NO BOARD
This is normal if the test is being done when (a) the board is not physically in the system or (b) the system is booting up. Otherwise, there is some inconsistency between the physical configuration and the data kept in the system.
Verify that the board is physically in the system.
Verify that the system is not in a stage of booting up.
Retry the command at 1-minute intervals for a maximum of 5 times.