ERS 4000 : Power Outage / Shutdown Procedure


Doc ID    ADMN111446
Version:    4.0
Status:    Published
Published date:    26 Nov 2014
Created Date:    07 Mar 2013
Author:   
arumikje
 

Body

 

The ERS 4000 does not need to be powered down before a power outage. However, if a power outage is anticipated, a manual backup of the configuration is highly recommended prior to the outage.
Please take a copy of both the binary and ASCII configuration. This is to make sure, we are fully equipped to handle any issues that may arise due to the outage.
 
Copying the binary configuration to a TFTP server:
Procedure:
1. Enter Privileged EXEC mode:
enable
2. At the command prompt, enter the following command to copy the running configuration to a TFTP server:
copy config tftp {address <A.B.C.D> | <WORD> | filename <filename>}
 
 
Copying the running ASCII configuration to a TFTP server:
Procedure:
1. Enter Privileged EXEC mode:
enable
2. At the command prompt, enter the following command to copy the running configuration to a TFTP server:
copy running-config tftp [verbose] [module <applicationModules>][filename <WORD>] [address {<A.B.C.D> | <WORD>}]
 
 
For further information on copying configuration or other methods to copy configuration: use  “Configuration — System Avaya Ethernet Routing Switch 4000 Series -  NN47205-500”.

 


Avaya -- Proprietary. Use pursuant to the terms of your signed agreement or Avaya policy