Found Minor PKT-BUS alarm on a Port Network (PN). Test passed but alarms are still present in the system. IPSI's are in service.
Footprints:
display alarms
ALARM REPORT
Port Maintenance On Alt Alarm Svc Ack? Date Date
Name Brd? Name Type State 1 2 Alarmed Resolved
PN 04 PKT-BUS n MINOR y 04/17/14:29 00/00/00:00
The status of the affected port network looks fine:
status port-network 04
PORT NETWORK STATUS
Major Minor Warning Carrier PN Control FIBER-
PN Alarms Alarms Alarms Locs Active Standby LINK Endpoints Mode
4 0 1 9 04A up up 4 A-PNC 04A03-21E19 active
04B 4 B-PNC 04B03-22E19 standby
TDM Service Control Dedicated TONE/ Service System System
Bus State Channel Tones CLOCK State Clock Tones
A in y y 04B in standby standby
B in n n 04A in active active
Service Major Minor Bus Open Bus
PKT State Alarms Alarms Faults Leads
4 in n y
tests are passed:
test packet-interface 04b
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
04B PKT-INT 888 PASS
04B PKT-INT 887 PASS