Install the CWY1
Board
|
This topic covers the following items:
Logging into the S8300 System Administration
Terminal (SAT) Command Line through Telnet
To login to the S8300 SAT command line:
- From your
laptop connected to the services port of
the S8300 Media Server or a customer P.C. with a connection
to the S8300 Media Server's LAN, click the
Start button on the lower left corner of your P.C. desktop.
The P.C. displays
the Start menu.
- Click the Run option.
The P.C. displays
the Run window.
- Type telnet <S8300_IP_address>
in the Open field, and click OK. Instead of the IP address, you
may also type the full domain name of the S8300 server (for example,
S8300.dr.acme.com). If you are connected through the services port,
use 192.11.13.5.
The P.C. displays the Login prompt in the
Telnet window.
- Type the login name in the Login field. Use craft, cust,
or another login administered for the S8300 Media Server. Do
not use sa or vm, which are for the INTUITY AUDIX
system.
- Type the password in the Password field,
and press ENTER.
The P.C. displays the Linux command line.
- Type sat and press ENTER.
The P.C. displays the Login prompt for the S8300 SAT command
line.
- Login again as in Steps 4 and 5.
The P.C. displays the SAT command line.
Shutdown and Turn Off
the S8300 Media Server

You must perform a graceful shutdown using your laptop or the
customer's PC before powering off the system. The system does
not have an on/off power switch. Disconnecting/reconnecting
the system to its power source is accomplished by unplugging
or plugging the power cord from/into its electrical outlet.
|
- At the S8300 SAT command line, type shutdown
and press Enter.
When the shutdown process completes, the system displays the following
message:
- Unplug your PC from the S8300 services port.
- Unplug the G700 from its power source.
Connect the CWY1 Board to the
S8300 Media Server
- On the front of the box, unscrew and remove the two thumb
screws that attach the S8300 face plate to the G700.
- Make sure you have your wrist strap on, then grasp the S8300 so
you have a firm grip on the LED panel and S8300 board at the same
time.
- Gently and firmly pull out the LED panel
and S8300 together.
- Place the S8300 board on a static-free surface.
- Complete Steps 6 through 9 to assemble the CWY1 and S8300 board
(see CWY1 and S8300 Assembly).
- Attach each of the two standoffs to the top of the S8300 from
the back of the S8300 using two of the four screws provided in the
kit. Make sure the screws are tightened securely; that is, until
firm resistance is met.
- Turn over the S8300 board and position the three female receptacles
on the CWY1 board over the three connectors on the S8300 board.
- Press gently and firmly until firm resistance is met, thereby
securely positioning the CWY1 board on the ICC.
- Use the remaining two screws to attach the CWY1 board to the standoffs.
Again, make sure the screws are tightened securely.
- Align the LED panel and the S8300 Board
and push both (together) back into the guides, gently and firmly
until the fronts of the boards align correctly with the front of
the unit.
- Reattach the S8300 faceplate with the thumb screws.
Reconnect the Power and Bring Up the System
- Plug the G700 power cord back into the designated
electrical outlet.
The system power comes on and the system boots up.
- Verify that the yellow ACT LED on the
S8300 board and the green CPU LED on the G700 Media Gateway are
lit.
|
 |
|
|