Previous page Next page

alarm-relative disable rtp

Disables relative alarms for RTP tests on any cell or edge that is assigned this alarm template.

You can control the generation of relative alarms for each measurement variable individually or all measurements collectively.

Syntax

alarm-relative disable rtp (all | delay | jitter | loss | inter-arrival-time)

no alarm-relative disable rtp

no alarm-relative disable rtp (all | delay | jitter | loss| inter-arrival-time)

Arguments
Table 11:  alarm-relative disable rtp arguments  
Argument
Description
all

Disables relative alarms for all RTP measurements: delay, jitter, loss, and inter-arrival-time.

delay

Disables relative alarms for RTP delay.

Delay is how long (in milliseconds one-way) it takes the UDP packet stream to reach its destination.

jitter

Disables relative alarms for RTP jitter.

Jitter is the unevenness in packet delay (in milliseconds).

loss

Disables relative alarms for RTP loss.

The loss threshold is a percentage of packets lost in transit.

inter-arrival-time

Disables relative alarms for RTP inter-arrival-time.

Inter arrival time is the time between tests, and can be used to trigger an alarm when a link is down or a set of endpoints becomes isolated.

Prerequisites

Must be in Chatter Alarm Configuration mode. For information on how to access this mode, see Accessing and exiting command modes.

Occurrence

Available for use multiple times in the configuration.

Default

Relative alarms are enabled for all RTP measurements.

Description

Disables relative alarms for RTP tests on any cell or edge that is assigned this alarm template.

You can control the generation of relative alarms for each measurement variable individually or all measurements collectively.

The no command restores the default value of enabled for all RTP measurements or the specified measurement variable.


Previous page Next page