Previous page Next page

efc last-update-within

Isolates IP addresses within a flow received from the optional EFC module according to when they last sent or received data.

Syntax
efc last-update-within <interval> 
 
                                 [ 
 
                                   seconds | 
 
                                   minutes | 
 
                                   hours | 
 
                                   days | 
 
                                   months | 
 
                                   years 
 
                                 ]
 
no efc last-update-within
 
Arguments
Prerequisites

Must be in active-measurement group configuration mode (config-engine-active), which requires privileged-level access.

Occurrence

Use once per active-measurement group.

Default

Interval units in seconds

Description

Use the efc last-update-within command to specify an interval of time in which IP addresses received from the optional EFC module must have sent or received data in order to be used as probe targets.

The efc last-update-within command is one of several commands which place restrictions on which endpoints obtained from the EFC module will be probed. See also:

You can use them together in the same active measurement group.

Use the no form of the command to remove the time restriction from the active-measurement group.

For more information about EFC, see Chapter 2: Collecting Endpoint Addresses of the CNA Basic Monitoring Guide.


Previous page Next page