If you execute the command as show statistics am-scheduler, the output will display information in several distinct blocks. The first block of display data gives you a high level summary of the active measurement system. The remaining sections show various active measurement statistics, such as probe rates attempted and completed, failures, DNS behavior.
ssf-neat-5008# show stat am-scheduler
Thu Dec 11 13:58:31 PST 2003
Current State: RUNNING
Start Time : 1071113800423 ms, 2003/12/10 19:36:40.423, 18h21m50s940ms ago
Reconfig Time: 1071176828121 ms, 2003/12/11 13:07:08.121, 51m23s242ms ago
Clear Time : 1071113800443 ms, 2003/12/10 19:36:40.443, 18h21m50s920ms ago
Last EFC Resp: 1071179911191 ms, 2003/12/11 13:58:31.191, 172ms ago
Debug Mode : off
Configuration Summary
Total Number of Targets : 84
Number of TCP Targets : 34
Number of ICMP Targets : 50
Number of Traceprobe Targets : 0
Number of Unknown Targets : 0
Configured Total Probes Per Second : 510.766667
Configured Max Probes Per Second : 1000.0
Multiplying rates by scale factor : 1.0
Expected DNS Lookups Per Second : 0.0
Configuration Errors
Group Target Type Error
Normal Events (per minute)
name total-count 1-min 5-min 60-min peak peak age
Tot Req Att 32030931 30214 30177 29246 31681 0d00:06:41
Tot Req Sent 32030931 30214 30177 29246 31681 0d00:06:41
TCP Req Att 74471 68 67 68 78 0d05:23:12
TCP Req Sent 74471 68 67 68 78 0d05:23:12
ICMP Req Att 31956460 30146 30109 29178 31609 0d00:06:41
ICMP Req Sent 31956460 30146 30109 29178 31609 0d00:06:41
Trace Req Att 0 0 0 0 0 0d18:21:50
Use Trace Cache 0 0 0 0 0 0d18:21:50
Trace Req Sent 0 0 0 0 0 0d18:21:50
Results Rcvd 32019819 30155 30179 29234 31218 0d00:06:52
Result Recorded 32019826 30155 30179 29234 31218 0d00:06:52
Trace Meas Sent 0 0 0 0 0 0d18:21:50
Trace No Conv 0 0 0 0 0 0d18:21:50
Bifurcated Prov 0 0 0 0 0 0d18:21:50
EFC Successes 128106 118 117 117 123 0d00:07:27
Fail Rpts Rcvd 17339161 16313 16313 15284 18798 0d14:22:04
Fail Rpts Sent 397196 446 447 437 989 0d14:22:10
Fail Rpts Supp 16941965 15867 15866 14847 17974 0d14:35:28
Error Events (per minute)
name total-count 1-min 5-min 60-min peak peak age
EFC Failures 0 0 0 0 0 0d18:21:50
EFC Timeouts 7 0 0 0 5 0d05:48:15
DNS No Host 0 0 0 0 0 0d18:21:50
DNS Timeouts 0 0 0 0 0 0d18:21:50
DNS Error 0 0 0 0 0 0d18:21:50
Unk Resolver 0 0 0 0 0 0d18:21:50
Req Connect Err 0 0 0 0 0 0d18:21:50
Runt Req Err 0 0 0 0 0 0d18:21:50
Req Send Err 0 0 0 0 0 0d18:21:50
Result Rcv Err 0 0 0 0 0 0d18:21:50
Times (in microseconds)
name 1-min 5-min 60-min peak peak age
DNS Time 0 0 0 0 0d18:21:50
EFC Time 2907 4113 4114 27408 0d05:47:40
Other
name 1-min 5-min 60-min peak peak age
Trace Cache% 0 0 0 0 0d18:21:50
Disabled Groups
Group Group Group
rs-web-clients Duplicate Targets
Group Target Type Rate Port
netscreen-targets 67.21.230.64 icmp 12/m n/a
rw-home 67.21.230.64 icmp 4/m n/a
Configured Target Diagnostics
group target type address
top-n-efc (EFC) icmp 12.2.41.18
VIP Definitions
Vip Ustat (Address)
(default) 4 (64.254.162.201), 5 (64.254.162.202), 6 (64.254.162.203)
The next block “Normal Events (per minute)” shows rolling averages of per-minute rates of probes sent. The 1-min column shows average probes per minute during the previous 60 seconds; the 5-min column shows average per-minute rate during the previous five minutes, and the 60-min column shows average per-minute rate during the previous hour.
The rows show totals for the various types of probes attempted and sent (e.g., the number of TCP and ICMP probes attempted and sent).
The requests sent values should be matched by requests received values in the show statistics am-measurer output.
Possible causes for a mismatch between sent and received values are: DNS lookup of target’s host name failed, and an internal error. The average DNS lookup times should be short enough to handle the number of lookups expected.
The block titled “Error Events (per minute)” has the following:
The block titled “Times (in microseconds)” shows the following:
If you have configured a greater number of probes per second than allowed by the probe-backoff command, the CNA system will scale back the number of probes to conform with the limit. See Measurement Frequency earlier in this chapter for more information.
See the active-measurement group command in the CNA Command Reference Guide for more information about configuring target parameters for probes that are defined in an active measurement group.)
|
|
|