DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Set the 7400B+ Data Module Options

Return to Task List

  1. Set the DIP switches for the 7400B+ using DIP Switch Settings (7400B+).

  2. The DIP switches are located inside the unit. To access them, remove the power cord from the unit, remove the cover from the top rear of the unit, set the dip switches, replace the cover, and connect the power cord.

    The unit performs a self test.

  3. If any switches were set in step 1, cycle the power to the data module so that the firmware can read the new switch settings.

DIP Switch Settings (7400B+)

Option

DIP Switch

Setting

No Telephone Connected

1

On

Data Metering

5

Off

Suppress Touch-tone/Dial Tone

6

Off

Speakerphone Disable/Enable

7

Off

Busyout on Local Loop

8

Off

Unused DIP Switches

2, 3, and 4

Off

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.