Off-Premises Protection Requirements

Return to Task List

Both building entrances require carbon block or equivalent protection and sneak current protection. Protection can be provided by:

The 4-type protector is the preferred device. For installations not using primary protection, 4-type protectors should always be used. When the 3-type protector is already installed, a separate sneak current protector is required.

The multi-pair protector units and the off-premises cabling must be locally engineered. Connectorized multi-pair protector units (female 25-pair connector) are recommended. Analog Line Circuit Protectors shows the recommended protectors.

The protectors can be ordered from the Premises Distribution Systems Equipment and Supplies Catalog.

Analog Line Circuit Protectors

Primary1

Primary
(with heat coil)

Sneak Current
Protectors 1

3B1A (carbon)

4B1C (carbon)

220029 Fuse

3B1E-W
(wide gap gas tube)

4B1E-W
(wide gap gas tube)

SCP-1

3C1S
(solid state)

4C1S
(solid state)

 

1
The 3-type protectors should be used only if they are already part of the existing protection system. A sneak current protector is always required when a 3-type primary protector is used.

Return to Task List