Test Telephones and Other Equipment
Test Duplication Option Processing Element Interchange
The process of the standby Processing Element (PE) taking over for the active PE is referred to as a PE Interchange. This interchange should not be performed immediately after powering up the system. Wait a few minutes to allow the system to complete its internal tests. The system default is PE_B after powering up the system, so the active PE should be the B processor for this test, and the interchange should make PE_A the active PE. Verify the system can successfully perform a PE interchange.
- At the management terminal, verify the screen displays PE_B in the upper right corner.
- Type check status and press Enter. Verify PE_B is in the standby mode. If it is, proceed to Step 4. If it is not, proceed to Step 3.
- Type refresh-spr-standby and press Enter.
- Type reset system interchange and press Enter. The management terminal will be logged off and a beep will be heard.
- Login and verify that the screen displays PE_A in the upper right corner.