DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Test Terminating Trunk Transmission

Return to Task List

The Terminating Trunk Transmission Test provides for extension number access to 3 tone sequences that can be used for trunk transmission testing from the distant end of the trunks.

The 3 test types must have extension numbers assigned on the system-parameters maintenance form:

 Test Type 100:_______	 Test Type 102:_______	 Test Type 105:_______

Test Type
Test Features

Test type 100

5.5 seconds of 1004 Hz tone at 0 dB

Quiet until disconnect; disconnect is forced after 1 minute

Test Type 102

9 seconds of 1004 Hz tone at 0 dB

1 second of silence

Cycle is repeated until disconnect, which is forced after 24 hours

Test Type 105

9 seconds of 1004 Hz tone at -16 dB

1 second of silence

9 seconds of 404 Hz tone at -16 dB

1 second of silence

9 seconds of 2804 Hz tone at -16 dB

30 seconds of silence

0.5 seconds of test progress tone (2225 Hz)

About 5 seconds of silence

Forced disconnect

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team