Record all links and remove only ISDN interface links [G3V4vs, R5vs, R6vs to R10si]

Return to Task List

For R7 and later, ISDN links move to the Net Packet circuit pack. They are not retranslated. If you are upgrading from any release earlier than R7, you remove the ISDN links and do not readminister them.


Note: Any BX.25 adjunct links to adjuncts (for example, CMS, AUDIX, INTUITY, or others) that are to be retained will still reside on the existing TN765 processor interface (P/I) in the designated P/I slot. Remove the TN765 P/I only if the sales team has specified that all adjunct connectivity is being migrated to a TN799 Control LAN (C-LAN) circuit pack.

Use this procedure to identify, record, and remove the ISDN links from the communication link and communication processor forms:

  1. Type display communication-interface links and press Enter. If any links were administered on this form, note them.

  2. For each link where the Prot field is ISDN, record the information in all fields.

  3. If you must back out of the upgrade, you will need this information.

  4. For each ISDN link, type busyout link [link] and press Enter.

  5. Type change communication-interface links and press Enter.

  6. For each link where the Prot field is ISDN, type n in the Enable field and press Enter.

  7. Type display communication-interface processor-channels and press Enter.

  8. For each processor channel where the Application field is ISDN, record the information in all fields.

  9. If you must back out of the upgrade, you will need this information.

  10. Type change communication-interface processor-channels and press Enter.

  11. For each processor channel where the Application field is ISDN, clear the information from all fields and press Enter.

  12. Type change communication-interface links and press Enter.

  13. For each PI extension where the Prot field is ISDN make these entries:

Field
Value  

Est Conn

n

Prot

bx25

DTE/DCE

dte

Identification

[blank]

  1. Press Enter.

  2. For each PI extension where the Application field is ISDN:

    1. Type display data-module [PI EXT] and press Enter. Record the information in each field.

    2. If you must back out of the upgrade, you will need this information.

    3. Type remove data-module [PI EXT] and press Enter.

Return to Task List