DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC



Save translation [G3V4vs, R5vs, R6vs to R10si]

Return to Task List


Note: To save translations on duplicated systems, the systems must be in sync or the command will fail. For duplicated systems, type status system 1 and press Enter.

Verify that conditions are normal (this can take as long as 5 to 10 minutes). If the system refuses to go into a normal condition, refer to the maintenance procedures; if that fails, escalate the problem.

  1. Type save translation and press Enter.

  2. This takes about 10 minutes.


Note: Do not press any keyboard key until after the terminal displays the success message. For example, if you press Enter more than once after typing the command, the second Enter erases the screen and you never see the success message.

  1. It the save translation command fails, do not continue. Record the error code that appears on the screen and escalate the problem immediately.

  2. Keep the translation card in a safe and secure place. In case of failure, you use this translation card to return the system to the old load.

Return to Task List


DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for si Go to Installation for MCC Go to Installation for SCC
Copyright 2001 Avaya Inc.
Send comments to MadeEasy Development Team



Always check at the Made Easy Web site for the most current information.