DEFINITY Made Easy Tools
Issue 3, December 2001
R5/R6/R7/R8si to R10si
Verify the upgrade [R10si]
- Execute status system 1 and verify that the system is in a normal state.
- Type display alarms and press Enter.
- Type list configuration software-version (simplex) or list configuration software-version long (duplex) and press Enter. Check the Memory Resident field to verify that it shows the correct Release 10 software load.
- Type display communication-interface links and press Enter.
If the system is not alarm-free, take the needed corrective actions.