Special Administration Requirements

Duplicated si systems, release 7.1 or later, must have the SPE Interchange field set correctly, or the system will sometimes generate packet alarms that will prevent ISDN from working properly.

Type change system-parameters maintenance to display the MAINTENANCE-RELATED SYSTEM PARAMETERS form and verify that the SPE Interchange field is set to daily.

 display system-parameters maintenance                           Page   1 of   4
                    MAINTENANCE-RELATED SYSTEM PARAMETERS
 
 OPERATIONS SUPPORT PARAMETERS
             Product Identification: 1020000942
         First OSS Telephone Number: 18004513036        Abbrev Alarm Report? y
        Second OSS Telephone Number:                    Abbrev Alarm Report? n
   Alarm Origination to OSS Numbers: first-only
         Cleared Alarm Notification? n                 Suspension Threshold: 5
               Restart Notification? y
            Test Remote Access Port? y
         CPE Alarm Activation Level: minor
 
      Customer Access to INADS Port? y
        Repeat Dial Interval (mins): 7
 
 SCHEDULED MAINTENANCE
                   Start Time: 05 : 00                   Stop Time: 06 : 00
            Daily Maintenance: daily              Save Translation: daily
                                          Command Time-out (hours): 2
  Control Channel Interchange: no        System Clocks Interchange: no
              
SPE Interchange: daily          EXP-LINK Interchange: no
 