- Type in the following information for the TN2302AP IP Media Processor and TN799B/C C-LAN:
- Set
Slot field to
UUCSS.
- The
Code and
SFX fields are automatically populated with TN799B/C and TN2302AP.
- In the
Node Name field type the same node name entered on the Node Name screen.
- In the
Subnet Mask field use the default setting unless you are given a different subnet mask.
- In the
Gateway Address field use the address you are given or leave blank.
- Set the
Net Region field to
1 unless you are given a different number.
- Set the
Enable Eth Pt field to
y
- Press
Enter to save the information and effect the new settings.
Refer to the
DEFINITY Enterprise Communications Server Release 8 Administration for Network Connectivity
for more information on these administration steps and for the steps to administer IP Softphones and H.323 trunks.