DEFINITY Made Easy Tools
Issue 2, November 2000
Install and Wire Telephone Power Supply
Install the Battery Mounting/Wiring
Three types of back-up batteries are used. See Back-Up Battery Rating and PECs for the battery type, rating, and price element code (PEC).
- Insert two #10-32 x 1/2-inch shoulder screws into the top designated battery holes on the wall mounting plate. Lightly screw in but do not tighten.
- Place the keyhole slots in the battery bracket on these two screws. The battery cord exits from the right of the bracket. Make sure the label on the battery is visible. Tighten the screws securely.
- Plug the battery cord into the power supply's right rear receptacle. The rear receptacle is indicated on the right label.