DEFINITY Made Easy Home Page Table of contents Previous page Next page Index Links Frequently asked questions
Go to Upgrades for R9 Go to Installation for MCC Go to Installation for SCC



Check the Active Tone-Clock (High/Critical reliability only) [R9r]

Return to Task List

  1. Type status port-network 1 and press Enter to verify that the Tone-Clock and the active SPE are in the same carrier.

  2. Verify that the Service State field shows in.

  3. If the Tone-Clock and active SPE are not in the same carrier, type set tone-clock [A | B] and press Enter .

  4. This command sets the Tone-Clock to the same carrier as the active SPE.

    If the active Tone-Clock has not migrated to the active carrier after 1 minute, then a Tone-Clock problem exists. Refer to the TDM-CLK Maintenance Objects section of the DEFINITY Enterprise Communications Server Release 9 Maintenance for R9r book to resolve any problems.