Migrating from DEFINITY AUDIX
This procedure migrates these releases of DEFINITY AUDIX to the Avaya Intuity:
Customers can migrate to the Intuity AUDIX system from one of two possible configurations of the DEFINITY AUDIX system:
- Control Link (CL) mode
Replaces the DEFINITY AUDIX system and uses the existing control link cable and data link administration for the Intuity AUDIX system.
- Digital Port emulation (DP) or Display Set (DS) mode
Replaces the DEFINITY AUDIX system but requires the installation of a data link cable and administration of the integration for the Intuity AUDIX system.
Migration Checklist
To migrate from a DEFINITY AUDIX R3.1, 3.2, or 4.0 system to the Intuity AUDIX system:
Area TaskPreparing for the migration
- Assemble the Intuity AUDIX system. For more information, select your MAP under Assembling the System.
- Restore power to the Intuity AUDIX system.
- Contact the MMIS to run a file system check.
- Remove the DEFINITY AUDIX ports from the switch hunt group.
- Install the migration software on the Intuity AUDIX system.
Migrate the data
- Connect the tape drive and transfer the data.
Note: If the Intuity AUDIX is a MAP/5P, the SCSI interface card is installed during this task.
- If the Intuity AUDIX is a MAP/5P, then follow Removing the SCSI Interface Card.
Complete the administration
![]() http://www.avaya.com Avaya UCS Information Development |
![]() |
![]() |
![]() |