Administering the Avaya Intuity System for Integration with a System 85 Switch

This section contains procedures to administer the Avaya Intuity system for integration
with a:

Updating the DCIU Interface Administration Window on a Non-DCS Network


 


When you update the DCIU Interface Administration window, the system resets the DCIU switch link.

To update the DCIU Interface Administration window on a Non-DCS network:

  1. Start at the Avaya Intuity Main Menu and select:
  2. Switch Interface Administration
    DCIU Interface Administration

    The system displays the System 85 DCIU Interface Administration Window.

  3. Confirm the information entered at the top of the System 85 DCIU Interface Administration Window.
     

    Note: The extension length entered in the Extension Length: field must match the dial plan on the switch. This will be either 3, 4, or 5.

  4. Enter the number of the host switch in the Host Switch Number: field. Valid host switch numbers range from 1 to 20.
     

    Important! The default for the host switch on a non-DCS integration is usually 1.

  5. Enter the logical channel number in the Logical Channel field.
     

    Important! The logical channel must be the same number as the Interface Link and the Remote Processor Channel on the switch.

  6. Enter the switch port in the Switch Port field. Valid switch port numbers range from 1 to 1864.
  7. Press F3 (Save).
  8. The system displays a message that indicates the switch link is resetting.

  9. Press F6 (Cancel) to return to the Avaya Intuity Main Menu.
  10. You have completed the system administration required for a non-DCS network integration with a System 85 switch.

Updating the DCIU Interface Administration Window on a DCS Network

To update the DCIU Interface Administration window on a DCS network:

  1. Start at the Avaya Intuity Main Menu and select:
  2. Switch Interface Administration
    DCIU Interface Administration

    The system displays the System 85 DCIU Interface Administration Window.

  3. Confirm the information entered at the top of the System 85 DCIU Interface Administration Window. Enter the number of the host switch in the Host Switch Number: field. Valid host switch numbers range from 1 to 20.
     

    Important! In a DCS network, enter the number of the host switch that connects directly to the system. The number must match the DCS node number on the switch.

  4. Enter this Machine-ID number in the AUDIX Number: field.
  5. Enter the logical channel number in the Logical Channel field.
     

    Note: The logical channel is the same number as the Interface Link and the Remote Processor Channel on the switch.

  6. Enter the switch port in the Switch Port field.
  7. Press F3 (Save).
  8. The system displays a message that indicates the switch link is resetting.

  9. Press CANCEL to return to the Avaya Intuity Main Menu.
  10. Continue with Administering the DCS Network Time Zone.

Administering the DCS Network Time Zone

To administer the time zones for the individual switches in the DCS network:


 

Note: This procedure does not change the time zone assignment for the host switch connected to the system.

  1. Start at the Avaya Intuity Main Menu and select:
  2. AUDIX Administration

    The system displays the AUDIX Command Prompt Screen.

  3. Enter change switch–time–zone at the enter command: prompt.
  4. The system displays the Change Switch-Time-Zone Command Output Screen.

  5. Enter the time zone and the daylight saving values for each switch.
  6. Press F3 (Enter).
  7. Enter exit to return to the Avaya Intuity Main Menu.
  8. You have completed the system administration required for a DCS network integration with the System 85 switch.
  9. Stop the voice system.
  10. Continue by restarting the voice system.